Gateway PROFIBUS DP to Serial (ASCII) or Modbus RTU

Gateway PROFIBUS DP to Serial (ASCII) or Modbus RTU

308,00

Quickly available!

netTAP 50 connects to communication networks and acts as a Gateway for simple conversions between one Real-Time Ethernet protocol (1-port) and one fieldbus protocol or one serial automation protocol as well as between one fieldbus protocol and one serial automation protocol. netTAP 50 supports Slave-zu-Slave- and Slave-zu-Master-conversions. As a master, netTAP 50 provides only one single slave device with the full master function. This makes it easy to integrate a single field device into any higher-level network.

The design of the netTAP 50 convinces by its compact hardware and is reduced to the basic requirements of a protocol converter. The converter is directed to market segments for which the factor costs has priority. This makes the netTAP 50 an attractively priced and universally applicable gateway that offers a wide variety of conversion options.

NT 50-DP-RS supports the following protocols:

  • PROFIBUS DP Slave
  • PROFIBUS DP Master
  • Serial (programmable)
  • Serial (ASCII)
  • Modbus RTU Master
  • Modbus RTU Slave
  • Integrates a Modbus RTU device into a PROFIBUS DP network, and vice versa
  • Transfers ASCII telegrams from/to a PROFIBUS DP Master or Slave
  • Extremely space-saving compact design
  • Loadable Firmware for flexible use of other conversions
  • With diagnosis and configuration interface via Ethernet
Communication controllerCommunication controllernetX 50
Integrated MemoryRAM8 MB SDRAM
FLASH4 MB serial Flash
Power supplySupply voltage24 V ± 6 V DC
Current consumption at 24 V (typically)72 mA / 150 mA (with short circuit at the output of PROFIBUS)
Typical power consumption1,8W
Communication interface 1Communication interfacePROFIBUS DP
Interface typeRS-485, optically isolated
Connector typeD-Sub female, 9-pin
Communication interface 2Communication interfaceSerial interface
Interface typeRS-232, RS-422, RS-485
Connector typeRJ45, Ethernet and serial interface together in one connector
Permitted ambient conditionsAmbient temperature (operation)0 … +60 °C
Relative humidity (operation)no condensation allowed
DeviceDimensions (L x W x H)100 x 26 x 66 mm (without connector)
Weightappr. 80 g
Degree of protectionIP 20
Mounting typeon DIN rail EN 60715
ConfigurationConfiguration softwareSYCON.net

Description

Order number

NT 50-DP-RS - Gateway PROFIBUS DP to RS-232/422/4851758.100

Manuals

Configuration of Gateway and Proxy Devices Versie: Rev. 12
netTAP_NT_50_-_Gateway_Devices_UM_18_EN-2.pdf Versie: Rev. 18

Technical documentation

netTAP-50_Datasheet_05-2020_GB.pdf Versie: 05-2020
vraag meer informatie over toepassingen aan via ons contactformulier.