Gateway PROFIBUS DP Master to PROFINET IO Device

Gateway PROFIBUS DP Master to PROFINET IO Device

High-End Gateway for demanding conversions

netTAP 100 is the protocol converter for sophisticated conversions and supports 2-port Real-Time Ethernet to serial, Fieldbus to Fieldbus, Real-Time Ethernet to Fieldbus and Real-Time Ethernet to Ethernet conversions. It supports slave and master functionality in any combination. Master functionality is unrestricted when licensed.

A memory card slot allows the user to save firmware and configuration data on a removable card. In case of failure all that is necessary to bring the plant back on line within seconds is to move the memory card from the old netTAP 100 onto a spare unit.

Apart from standard protocols, netTAP 100 supports the creation of serial protocols with the Lua-based scripting language netSCRIPT. A full featured development environment is included within the delivery. It allows the comfortable and rapid programming of any proprietary serial protocol as well as the I/O data pre-processing during the conversion into the other field protocol.

  • Integrates a subordinate PROFIBUS network trunk in PROFINET
  • Master for up to 125 PROFIBUS slaves
  • Shortest I/O data conversion time lower than 10 ms
  • Device replacement in seconds via memory card based loading
  • Loadable firmware for flexible use of other conversions
  • With USB diagnostic and configuration port
Communication controllerCommunication controllernetX 100
Integrated MemoryRAM8 MB SDRAM
FLASH4 MB serial Flash
Memory cardType and size SD or MMC card, max. 2 GByte
Power supplySupply voltage24 V ± 6 V DC
Current consumption at 24 V (typically)Maximum Current at 24 V (typically) 130 mA
Typical power consumption3,2W
Requirement to the power supplyFor UL conform usageDevice shall be supplied by an isolated voltage source
Communication interface 1Communication interfaceEthernet
Interface type100 BASE-TX or 10 BASE-T, isolated
Connector type2 * RJ45
Communication interface 2Communication interfacePROFIBUS DP
Interface typeRS-485, optically isolated
Connector typeD-Sub female, 9-pin
Operating elementsNetwork addressNetwork address, 2 rotary switches
Permitted ambient conditionsAmbient temperature (operation)0 … +60 °C
Relative humidity (operation)no condensation allowed
DeviceDimensions (L x W x H)100 x 52 x 70 mm (without connector)
Weightappr. 150 g
Degree of protectionIP 20
Mounting typeon DIN rail EN 60715
ConfigurationConfiguration softwareSYCON.net

Omschrijving

Bestelnummer

NT 100-RE-DP - Gateway PROFIBUS DP to Ethernet1712.180
NXLIC-MASTER - Master license8211.000