sensorEDGE FIELD – Edge IO-Link master with remote management option
sensorEDGE FIELD – Edge IO-Link master with remote management option
Instant-IO-Link solution for remote monitoring your sensor data
sensorEDGE is Hilscher’s solution for the fast remote monitoring of your machines. Equipped with two netIOL chips (an IO-Link master controller developed by Hilscher) and a cloud uplink, the sensor box allows the remote data monitoring and analysis of up to eight IO-Link sensors.
A power supply and an internet connection is all sensorEDGE needs. A complex setup of the PLC and the fieldbus system is not required.
As soon as sensors are plugged in and autonomously configured via the IODD (from an Internet file database), the sensor box transmits data into the cloud at 1-second intervals. The data can be visualized directly in the corresponding cloud web frontend or accessed via an API from any third-party application.
sensorEDGE is the ideal solution for retrofitting existing plants that have so far been controlled locally but never monitored remotely. The sensor box is compatible with all IO-Link sensors, that operate in accordance with protocol standard IEC 61131-9, and can thus be integrated with a minimum effort. The IP67-rated casing withstands the harshest conditions making it ideal for installations outside a switch cabinet close to your machine.
- Connection of up to 8 local IO-Link sensors
- Freely usable CPU processing power of 1.6 GHz Quad-Core ARM 64-bit
- Sensor data and information accessible via internal MQTT bus
- Including IO-Link web configurator and data converter from IO-Link to MQTT
- Extendable by IoT applications developed by the customer using any containers
- Central device/container management possible via cloud portal
Vraag direct een offerte aan!
sensorEDGE FIELD – Edge IO-Link master with remote management option
Neem contact op voor de actuele levertijden.
General | Part number | 1915.231 |
Functions | 8-port IO-Link Master (Class A) Edge Device with remote management option | |
Power supply | Supply voltage | +24 V DC, –25%/+30% (18 V DC … 31.2 V DC) Note: Voltages above 34 V may cause permanent damage to the device. Voltages below approx. 10 V will cause a shutdown of the device. Note: The sensorEDGE does not need or use auxiliary supply voltage (U2L), even though the pins for the 2L auxiliary load circuit are implemented on the device. The 1L and 2L load circuits are galvanically isolated from each other. |
Under-voltage warning | U1L < 18 V: 1L LED shows steady red U1L > 17.7 V: 1L LED returns to steady green | |
Over-voltage warning | U1L > 30 V: 1L LED blinking red (4 Hz) U1L < 29.7 V: 1L LED returns to steady green | |
Current consumption (typical) | 150 – 160 mA (at 24 V DC) | |
Maximum current at supply connector | 16 A with airflow of ~ 0.5 m/s. 3.36 A without airflow Note: Always protect the power supply with a circuit breaker or fuse. For this purpose, use a 24 V DC / max. 16 A fuse or circuit breaker with type B trip characteristics. | |
Reverse voltage protection | Yes | |
Mains buffering (power failure bridging) | 10 ms (at 24 V) | |
Connector | M12 L-coded, male, 5-pin (4 + FE) Recommended tightening torque of locking nut: 0.4 – 0.6 Nm | |
Mechanics and housing | Dimension (L x W x H) | 200 mm x 60 mm x 30 mm |
Weight | 420 g | |
Housing material | Glass fiber reinforced plastic (PBT) according to UL 94-V0 Note: The housing is not UV resistant. Avoid long-term exposure of the device to direct sunlight. | |
Housing color | RAL 7035 (“light gray”) | |
Degree of protection | IP67 (EN 60529) | |
Protection class | III (EN 61140) | |
Mounting type | To be attached to carrier with two M4 screws. Recommended tightening torque: 0.8 Nm | |
Admissible ambient conditions | Ambient temperature for operation | –25 °C … +60 °C at maximum current consumption per IO-Link port of 400 mA without airflow. –25 °C … +60 °C at maximum current consumption per IO-Link port of 1800 mA with airflow of ~ 0.5 m/s. |
Ambient temperature for storage | –40 °C … +85 °C | |
Max. temperature change | 3 K / min | |
Relative humidity (operation) | 5 % … 95 % | |
Pollution degree | 3 (EN 60664-1) | |
Altitude | 0 ... 2000 m | |
Overvoltage category | II (EN 60664-1) | |
Electromagnetic compatibility (EMC) | Radio Interference Field Strength Emission | DIN EN 55016-2-3 / BS EN 55016-2-3 |
Radiated Field Immunity | DIN EN 61000-4-3 / BS EN 61000-4-3 | |
Conducted Disturbances Immunity | DIN EN 61000-4-6 / BS EN 61000-4-6 | |
Radio Interference Voltage Emission | DIN EN 55016-2-1 / BS EN 55016-2-1 | |
ESD contact discharge | DIN EN 61000-4-2 / BS EN 61000-4-2 4 kV | |
Burst | DIN EN 61000-4-4 / BS EN 61000-4-4 | |
Surge | DIN EN 61000-4-5 / BS EN 61000-4-5 | |
Mechanical tests | Vibration sinusoidal | DIN EN 60068-2-6:2008 |
Shock | DIN EN 60068-2-27:2010 | |
Free fall | DIN EN 60068-2-31:2009 | |
Approvals | UL | In preparation |
Conformity declarations | CE | Yes |
UKCA | Yes | |
RoHS | Yes | |
REACH | Yes | |
Ethernet LAN interface | Type | 10/100 MBit/s Ethernet port (eth0) |
Connector | M12, D-coded, female, 4-pin. Recommended tightening torque of locking screw: 0.4 – 0.6 Nm | |
IO-Link | Type | IO-Link Master, Class A, 8 ports |
Connector | 8 x M12 A-coded, female, 5-pole Recommended tightening torque of locking screw: 0.4 – 0.6 Nm Maximum cable length: 20 m. | |
LED indicators | SYS (green/yellow) | “System” status LED of the communication controller |
WiFi Symbol Wi-Fi/Bluetooth (blue) | Currently without function (reserved for future use) | |
EDG (red/green) | “Edge” LED indicating configuration and operating states of the IO-Link sensors | |
CLD (red/green) | “Cloud” LED indicating connectivity with the Internet/cloud | |
RUN (red/green) | Currently without function (reserved for future use) | |
ERR (red/green) | Currently without function (reserved for future use) | |
LINK (green) | Ethernet Link status | |
ACT (yellow) | Ethernet Activity status | |
1L (red/green) | Indicates supply voltage status | |
2L (green) | Indicates supply voltage status of second load circuit (U2L). Note: The sensorEDGE does not need or use auxiliary supply voltage (U2L), even though the 2L LED and the pins for the 2L auxiliary load circuit are implemented on the device. | |
8 x A (red/green/yellow) | Status of the IO-Link port (Note: Yellow is produced by switching red and green duo LED on at the same time) | |
8 x B (red/green/yellow | Not used |
Omschrijving |
Bestelnummer |
sensorEDGE FIELD - Edge IO-Link master with remote management option - NFS-M8-QM-D2-N16/NFLD | 1915.231 |